Nailor vav box. reserves the right to change any information concerning product or pricing without notice. Nailor vav box

 
 reserves the right to change any information concerning product or pricing without noticeNailor vav box • VAV section is lined with 13/16" (21), thick, 4 lb

Nailor 3400 Series Bypass Terminal Units are designed to provide. The primary air was stillNailor Industries Inc. Nailor Industries Inc. The 37S and 37SST Series Low Profile terminals are designed for shallow ceiling plenum applications and therefore limited to 11" (279) in height. 3 - 10 - 23 UNI2-VAV VARIABLE AIR VOLUME (VAV) DIFFUSER SQUARE PLAQUE • CORNER POSTS ROUND NECK • STEEL MODEL: UNI2-VAV Nailor Industries Inc. • VAV section is lined with 3/4" (19), dual density insulation, exposed edges coated to prevent air erosion. The simplified version of this decision is Series Units for all zones or Parallel units on the exterior and single-duct for interior zones. CSA C22. NFB-VCHD - VAV Round Floor Boot with Actuator . The sale of certain items may be geographically restricted. ACC. 02" w. Dimensions are in inches (mm). AT35SE - 3’ Long • for Models 35SE and 35SEST. A non-programmable thermostat is required on master units and controls up to 20 different diffusers. A box with a fan (series or parallel)is more of a mixing box because it mixes plenum air with supply air from the air handler. Nailor was assigned the task of developing a custom UFAD system. DATE B SERIES SUPERSEDES DRAWING NO. “The sequences are necessarily complex in. 江森自控VAV变风量空调系统的核心部分,便是Titus®变风量末端。 自1946年开始,江森自控旗下的Titus(泰德思)便成为世界范围建筑师、工程师和承建商首选的空调送气产品。下面就来看一看,江森自控Titus®VAV变风量末端究竟具备何种实力,可以达成这样的成绩。Nailor Industries, Inc. , Unit #2, Vaughan, ON L4K 2W4 The warehouse is filled with hundreds of products made by Nailor Industries. Category:. The thermostat communicates the occupant’s expectation for thermal comfort. shaft Table 8: Nailor Industries, Inc. +. 4 - 17 - 20 VAV-FF TERMINAL UNITS LINER OPTIONS SOUND POWER LEVEL CORRECTION FACTORS TYPE: FIBER-FREE INSULATION CHARACTERISTICS Material: Engineered Polymer Foam Insulation (EPFI). q 24 VAC control transformer. Nailor GTA stocks all the standard Diffusers, Grilles/Registers, VAV Boxes, Curtain Type Fire Dampers, Fire Stop Flaps, Access Doors, Damper Actuators and Fans to meet the most common. pressure to overcome the losses across the damper, the . Ø8″. and our comprehensive line of Air Distribution, Air Control and Air Terminal Unit products. Nailor VAV Box Titus VAV Box. Nailor Subject: Terminal Units Fiber-Free Liner Options Sound Power Level Correction. A. Retrofit Terminal Units. Nailor 5600 Series plenum slot diffusers feature a roll-formed curved blade pattern controller in each slot. Critical Room. Complete Air Control And Distribution Solutions: Grilles Registers Diffusers VAV Terminal Units Fire Dampers Smoke Dampers Control Dampers Radiation Dampers LouversNailor Industries Inc. Digital VAV Controllers shall be responsible for monitoring and controlling directly connected VAV Terminals as required. The. Its strongest suits are the VAV box and silencer selection sections. Grainger carries one I believe, but I cannot find it online. SRDV, SRPV. 8" VAV BOX NAILOR VAV BOX 8 INLET. Page 3 of 3 Dimensions are in inches (mm). Designed for both stand-alone applications and for integration with BACnet building automation systems, EZvav are precise P+I pressure independent VAV controllers Selection of VAV terminals with a close coupled, independent silencer is a complex process with unpredictable results. 1940 – Robert E. (Houston). Heating and cooling equipment fans, heating and . This air handler configuration consists of custom-designed vertical air column units and VAV ECM fan booster boxes feeding perimeter linear convection heaters and high induction floor swirl diffusers in the interior that will be installed under the floors. 5 million cycles. VariTrane ® variable-air-volume (VAV) units lead the industry in quality and reliability and are designed to meet the specific needs of today’s applications. Airflow reported at the VAV box is actually a measure of total pressure. Brand: Nailor. INSTALLATION AND OPERATION MANUAL ELECTRIC HEATERS FOR. The main is considered upstream of the VAV box, while downstream of the box is considered the low-side supply. $38. For more information, please visit The new EZvav Digital Controls by Nailor bring simplicity to the Variable Air Volume (VAV) terminal unit market. At the minimum setting,Nailor 3600 Series Retrofit Terminal Units are designed for all applications and are engineered to transform inefficient constant volume systems to present day variable air volume systems with low installation costs. A DATE B SERIES SUPERSEDES DRAWING NO. Các VAV box. Factory calibrated controls must be selected within theThere are two different types of fan powered boxes; parallel and series. Dimensions are in inches (mm). A3400, A34RW E5 • Analog Electronic • Controls• VAV • Automatic Heating/Cooling Changeover w/ Auxiliary Heat (Perimeter Heating or Hot Water Heat). Nailor Industries Inc. When configuring the EVCB controller K factor, 515 would be entered. Nailor Industries, Inc. 6 - 26 - 09 NFD 5 - 15 - 09 NFD-VAV-1 VAV FLOOR "SWIRL" DIFFUSER CONTROL DIAGRAM UNDERFLOOR AIR DISTRIBUTION SYSTEMS VAV • COOLING ONLY MODEL: NFD-VAV Nailor Industries Inc. - RED connects to HIGH. Enhanced sequences to existing sections, such as an. Model Series 3600. Perforated Metal Liner. , operating under Nailor International Group is a privately held, family owned company with Group headquarters located in Houston, TX. . Electronic VAV Retrofit Kit. (0. Options and Accessories: q HW coil position: Box/Silencer/Coil (see page 2). 3 - 30 - 17 3000 3 - 21 - 13 30AT. Usually, inlet diameter determines VAV-box size. November 12, 2013 Agenda VAV Box Control Sequences AHU Control Sequences • Zone Groups • DP setpoint reset • SAT setpoint reset Outdoor Air Control • Minimum outdoor air control • Demand Controlled Ventilation AutomaticFault. SINGLE DUCT TERMINAL UNIT ACCESSORIES DIGITAL OR ANALOG CONTROLS MODELS: D3001 AND. The installing electrician should rotate the incoming electric service by phase to help balance the building electric load. SCHEDULE TPE: PROECT: ENINEER: CONTRACTOR: FAN POWERED TERMINAL UNIT WITH EPIC ECM MOTOR • HEAT ACCESSORIES SERIES FLOW • CONSTANT OR VARIABLE VOLUME MODELS: 35S, 35SW AND 35SE • UNIT. Gus Faris is vice president, engineering at Nailor Industries in Kingwood, Texas. VariTrane™ Fan-Powered Series Terminal. MRMS-B. Nailor Industries Inc. The sale of certain items may be geographically restricted. Available in several configurations, each 3000 Series is VAV box airflow rate commensurate with damper position and within minimum and maximum settings. Based on the graph, we can see that the maximum airflow for a 6" VAV box is 515CFM. Architectural Heaters; Electric Duct Heaters;. VAV BOXES WITH HOT WATER REHEAT: PROVIDE THE FOLLOWING FOR ALL AIR TERMINAL UNIT BOXES. NECC Controls offers a range of Nailor VAV Terminal Units for new construction, tenant fit-out, remodeling or replacement. Variable air volume (VAV) / Constant Volume boxes are great energy savers by delivering the exact amount of heated or cooled air to the conditioned space. The design achieves high. Archives. We invest relentlessly in product development, in both differentiated niche products and standard commodity products. We’re here to help you. This article will focus on cooling-with-electric-reheat VAV boxes. cooling circulation pumps, and terminal unit fans shall cycle off and terminal unit primary cooling air that building energy consumption with series and parallel FPTUs using PSC motors and operat-ing at. He offered a “Comparison of Room Noise Control For Series And Parallel VAV Units At Different Operating Conditions. 15 Flow Probe Amplification 229 358 515 702 916 1160 1432 2062 3665 7000 2806 4 inch 5 inch 6 inch 7 inch 8 inch 9 inch 10 inch 12 inch 14 inch 16 inch 22 inch 10 100 1000 10000 0. D3001 Single Duct Terminal Box 24x16 Inch Inlet. The thermostat communicates the occupant’s expectation for thermal comfort. Diffusers. The 35S offers a compact and economical design well suited to the majority of applications. Nailor manufactures its own electric heating coils. To give you a quick solution, below is the common diffuser sizes and their corresponded airflow. Dimensions are in inches (mm). Make installation adjustments as needed. The diffuser includes an actuator, linkage, plate damper, and diffuser. Request a Quote. For a given unit size, the minimum, auxiliary minimum (where applicable) and the maximum flow setting must be within the range limits to ensure pressure independent operation, accuracy and repeatability. As a result, this broad line of products is used by most major North. reserves the right to change any information concerning product or pricing without notice. Michael T. (Air Control & Air Distribution products, VAV Terminal Units, Green Products, Electric Duct Heaters), Engineered. Common applications include:VAV Box Types Fan Powered and Shut Off VAV Boxes waiting to be Installed Cool Only Single Duct Series VAV (non-fan powered) – The most basic VAV box I have ever seen was simply a box with a damper inside it that was controlled by an actuator. This control sequence is explained in detail in a previous article located here. Multiple Download been Selected. PEFM 4FSJFT 445 4UFBMUI Super Quiet, Series Flow (Constant. Model TSS terminals provide variable air volume (VAV) control beyond the typical single duct box. Viconics’ R820 SCR power controller has been designed for safe and reliable control of electric heat loads. Product offerings include Air Control & Distribution Products, VAV Terminal Units, Green Building Products, Fan Coil Units, Electric Duct Heaters, Sound Attenuators, Air Handling Units, and Filter Housings. Learn about the features,. Both standard height and low profile units are available. IOM. Nailor Curtain Type Fire Dampers Type: Type A, B and C – Both Static and Dynamic Certification: UL . The warmerNailor 3000 and 3100 Series Final Units are within the most versatile VAV boxes on aforementioned market, offer simply HVAC system integration with miscellaneous control packages. reserves the right to change any information concerning product or pricing without notice. UNITED STATES | CANADA | INTERNATIONAL. For 90° VAV boxes: If the damper closes CCW, turn the coupler to the CCW mechanical stop limit. CORE SELECTION: 5/32" (4) 1" (25) 1/8". The sale of certain items may be geographically restricted. Electric Heaters for VAV Terminal Units • 3000, 3200, 3400, 35S, 35SST, 37S, 37SST, 38S, 35N, 37N Series • Installation Instructions Epic Fan Volume Controller w/ Genteq EON ECM Motor Installation Instructions System Components. 7 Appendix B: VAV Controller Flow Calculation 7 Nailor Industries, Inc. Phone: 803. ELECTRICAL BOX (MASTER ONLY) CONTROL DISC. Single duct, parallel fan-powered, and series fan-powered units are connected to an air handling unit (AHU) that supplies the terminal units with cooled and dehumidified air. VAV System Design Considerations. Air Handling Unit & Ductwork. REVIT. 2 Heating/cooling system fan controls. The diffuser has a factory mounted controller, sensor and actuator. Basic Box* With Electric Coil With Attenuator ATT ATT5SP. V2080 - Controls Enclosure. AT35SW - 3’ Long • for Models 35S and 35SST. Johnson Controls Parallel Fan Powered Variable Air Volume terminals are available from 100 to 4100 cfm, providing flexibility in performance ranges to meet a multitude of system design requirements. This air is controlled by a fan, that is affected by the static pressure in the system. Nailor 3000 Series Single Duct Terminal units are, simply put, versatile. A common problem with standard pivoted single blade damper designs is objectionable noise and loss of modulation due to pulsating and/or a snap-closing action of the valve. The model you select might not exactly match the photo. This air is controlled by a fan, that is affected by the static pressure in the system. This is caused by a poor valve Figure 1: Support Using Hanger Straps (Shown: Model D30RW - Single Duct VAV Terminal Unit with Hot Water Heat). The Group consists of several business units: Nailor Industries, Inc. Designed for cooling only, cooling with reheat, heating only or heat/cool changeover applications. A17 SINGLE DUCT TERMINAL UNITS A SINGLE DUCT TERMINAL UNITS • 3000 SERIES Performance Data • Discharge Sound Power Levels 3000 Series • Basic UnitNailor was assigned the task of developing a custom UFAD system. Neck Size. The decks work in tandem to regulate the cold and hot airstreams to provide precise volume and temperature control for the conditioned zone. Nailor Curtain Type Fire Dampers Type: Type A, B and C – Both Static and Dynamic Certification: UL . As the load increases the supply of cool air increases and as the load decreases the air supply also decreases. reserves the right to change any information concerning product or pricing without notice. . Rep Locator ». ROOM THERMOSTAT WITH INTEGRAL TEMPERATURE. The diffuser has a factory mounted controller, sensor and actuator. Daikin VAV Controller is capable of controlling the following VAV pressure-independent zone applications. Standard Features: 22 ga. SelectWorks is designed to facilitate the work of Nailor's Manufacturers Representatives as well as Engineers and Contractors. , operating under Nailor International Group is a privately held, family owned company with Group headquarters located in Houston, TX. Single Duct Box. density Steri-Liner insulation. (0. From standard grilles and registers, to its architectural line of Formations® linear slot diffusers, along with a newly released series of displacement diffusers, METALAIRE has the air devices to meet every need. • Induction. TM UT TALLAT TAT DT 2 TM UT TALLAT TAT DT Manual priceindustriesco PRODUCT OVERVIEW Fan Powered Constant Volume Units – FDC-1-X, FDC-G2 This unit may be flipped 180°, and is provided with top and bottom access panels by default. Parallel fan terminals require enough static . Boiler System. Nailor 2 Row Hot Water Coils 14 Inch. VAV SPECIFICA TIONS 031600. Low Profile. These decisions must. NOTE: Product pictures shown represent the general type of device listed. Steel heavy duty return grille, 1/2" blade spacing, 38 degree deflection, blades parallel to long dimension. We’re here to help you. Finishes. Whether the requirement calls for a constant or variable air volume (VAV) single duct terminal, an electric or hot water reheat option or requires basic attenuation, the 3000 Series terminal units deliver. ALPATEC VLP 3005 VSIT User Manual Operation & user’s manual (12 pages) Rowenta HA 325 User Manual Instructions for use (4 pages) NOMA 052-1196-4 Instruction Manual Instruction manual (20 pages) ebm-papst D4E160-FH12-05 Operating Instructions Manual Operating instructions manual (11 pages)11 - 19 - 12 VAV. Multipoint crossflow sensor for accurate flow measurement. Pressure Independent VAV with Heater (Variable Air Volume Terminals) • Pressure Independent VAV Unit has one primary air inlet, one rectangular discharge outlet to the room and one rectangular bypass discharge outlet. . Nailor GTA stocks all the standard Diffusers, Grilles/Registers, VAV Boxes, Curtain Type Fire Dampers, Fire Stop Flaps, Access Doors, Damper Actuators and Fans to meet the most common requirements. Dual. SelectWorks is a simple, yet effective tool designed to aid the user in selecting and scheduling Nailor's VAV Terminal Units, Fan Powered Terminal Units, and Fan Coil Units. AT303 - Attenuator, 3 Foot Long. Nailor #300-205 TSTAT for VAV Electric Controls. COOLING WITH HOT WATER REHEAT • DIRECT ACTING, NORMALLY OPEN • VARIABLE AIR VOLUME • PRESSURE. 978. Nailor Industries Inc. A. Nailor Industries Inc. The primary air or cooling flow is set up just like a single duct vav. At the minimum setting, the damper in the existing terminal begins to modulate, and mixing occurs. Variable volume with or without mixing or constant volume applications. Ventilation System. Mason Company, Inc. Nailor 3000 and 3100 Series Terminal Units are among the most versatile VAV boxes on the market, providing easy HVAC system integration with diverse control packages. Airflow. 978. VAV Controls & Boxes. Select a state to see results. Contact Hahn-Mason Air Systems today at (704)-523-5000. The fan in the air handling unit will deliver the right amount of air to the system. Description. 978. Digital VAV Controllers shall be responsible for monitoring and controlling directly connected VAV Terminals as required. 17 1/2 in. ready access shall be provided to the manual unlocking devices and the device shall beair profile in the duct to even out before entering the box. reserves the right to change any information concerning product or. (1. When plotted on an RC chart, the 35SST tends to be “hissy”, while the 35SXC results in a RC 42N under the same conditions. Sub-Category: VAV Boxes . DATE B SERIES SUPERSEDES DRAWING NO. Nailor manufactures its own electric heating coils. The foil face provides a cleanable surface, making it suitable for many hospital and IAQ applications. Nailor 3200 Series Dual Duct Terminal Units are designed to maintain optimal temperature control in the conditioned zone by varying the air volume supplied by the hot and cold supply ducts while providing proper discharge air temperature. Quiet Type with dissipative silencers and Hospital Grade boxes are also available. Nailor 3000 and 3100 Chain Terminal Units are among an most versatile VAV boxes over the market, pro more. Nailor (President and CEO)2. When compared to a single duct terminal unit, the fan-powered versions have a fan that enables the induction of plenum air into the airflow. The equipment that work together to deliver occupant comfort in a VAV system includes the following: Chiller System. We are the best manufacturers & suppliers of variable air volume box, vav box, air volume terminal units & variable air volume system in Dubai, Abu Dhabi, UAE, Iran, Yemen, Israel, Oman, Qatar, Syria & North Africa. Fan noise in a fan-powered mixing terminal. SINGLE DUCT TERMINAL UNIT ACCESSORIES DIGITAL OR ANALOG CONTROLS PRESSURE INDEPENDENT. TYPE: SOLID METAL LINER (DOUBLE WALL CONSTRUCTION) Nailor Industries Inc. A true VAV box consists of an air valve and maybe a heat source only. The ductwork from the air handling unit is connected to the diffuser in the same way it connects to a standard diffuser. DATE B SERIES SUPERSEDES DRAWING NO. the existing box. Designed for control of hot or neutral and cold air. 2 - 6 - 23 3100 5 - 10 - 21 D31RW-OC-2 W L SLIP AND DRIVE CONNECTION H 51 1/2". Nailor 3000 and 3100 Series Terminal Units are among the most versatile VAV boxes on the market, providing easy HVAC system integration with diverse control packages. which the fan airstream was no longer parallel to the primary airstream. The following graph illustrates the difference between the 35SST (“Stealth”) and the 35SXC (“Stealth XC”) in exposed ceiling mockup tests. manufactures Air Control & Distribution products, VAV Terminal Units, Green Building products, Fan Coil Units, Electric Duct Heaters, Sound Attenuators, Air. Connect the airflow tubing for the Differential Pressure Sensor. NailorNailor 33SZ Series Fan Powered Chilled Water Terminal Units include a cooling induction coil to use in conjunction with a DOAS (dedicated outdoor air system) and is useful in a variety of commercial applications, such as office spaces, classrooms, critical environments and laboratories. Selection of VAV terminals with a close coupled, independent silencer is a complex process with unpredictable results. 5. The main is considered upstream of the VAV box, while downstream of the box is considered the low-side supply. The DOAS unit provides the Designer, Owner and Occupant with a series fan powered terminal unit which includes an integral chilled water sensible only coil at the plenum air inlet. reserves the right to change any information concerning product or pricing without notice. The associated thermostat is in the space and is. During this period, a new configuration appeared in . The previous version addressed only variable air volume (VAV) air-handling systems and terminal units. SelectWorks files are exportable and easily. Single duct, parallel fan-powered, and series fan-powered units are connected to an air handling unit (AHU) that supplies the terminal units with cooled and dehumidified air. 33RL. Their pleasing appearance blends well with. Maximum height of 10. Vav Zone Controllers. The following graph illustrates the difference between the 35SST (“Stealth”) and the 35SXC (“Stealth XC”) in exposed ceiling mockup tests. VAV System Design Considerations. aeFOR USE IN VAV SYSTEMS & FOR FLOW MEASURING SYSTEMS. A mechanical engineer must consider several variables and equipment types when designing a VAV system. 3, Room Air Distribution. Figure 1 is a diagram of a typical single-duct pressure- independent VAV box with hydronic reheat. 5 - 12 - 22 VAV. which the fan airstream was no longer parallel to the primary airstream. "Notch and tuck" fabrication and full seam length steel Z-strip construction. NECC offers Variable Air Volume controls, VAV boxes, VAV terminal units and controllers from Nailor, KMC, Kreuter, Johnson Controls. Options and Accessories: Steri-liner. 25 — 0. manufactures Air Control & Distribution products, VAV Terminal Units, Green Building products, Fan Coil Units, Electric Duct Heaters, Sound Attenuators, Air Handling Units, and Filter Housings. If you need help selecting the best unit for your application, call us at 800-227-9800. A series of research proects measuring energy and performance for fan-powered VAV terminal units FPTUs were conducted at Texas AM University, Texas AM atarTel: (0) 1842 765 657. in monitoring overall vav box performance. Nailor VAV Disconnect Switch. VariTrane® Fan-Powered Terminal Units. 3 - 30 - 17 3000 10 - 28 - 16 D3001-2 Page 2 of 2. Constructed as two single ducts, the 3210 consists of a dedicated hot and cold deck. The diffuser includes an actuator, linkage, plate damper, and diffuser. Do not The new location address will be 380 Bradwick Dr. 江森自控Titus®VAV变风量末端. Designed for both stand-alone applications and for integration with BACnet building automation systems, EZvav are precise P+I pressure independent VAV controllersNailor Industries, Inc. Pattern Diffusers. This situation is exacerbated in laboratories due to the wide range in internal loads (Figure 1). Download the submittal sheet for more details. q 20 ga. Thefanenergizesonlyin. D3001 - Single Duct Box • DDC Controls. The Group consists of several business units: Nailor Industries, Inc. Model Series 3600 are ideal for retrofit applications to convert Constant Air Volume Systems to Variable Air Volume. reserves the right to change any information concerning product or pricing without notice. For over 20 years Nailor has led the industry with the most innovative solutions for VAV systems. The VAV box section will help with hot water coil selection, which is. Variable air volume dampers. Nailor #300-205 TSTAT for VAV Electric Controls. Terminal units are used within a Variable Air Volume (VAV) System to control the airflow and temperature delivered to a zone. The 35S offers a compact and economical design well suited to the majority of applications. SelectWorks is designed to facilitate the work of Nailor's Manufacturers Representatives as well as Engineers and Contractors. All Nailor electric heaters are staged per specifications. Page 76: Mounting On A Vav Terminal Unit Mount the controller directly over the damper shaft. Specialists in. † Accurate readings at low air velocities amplified to usable signal pressures. fan boxes at the perimeter, and single damper VAV units were the rule. • VAV section is lined with 13/16" (21), thick, 4 lb. A common problem with standard pivoted single blade damper designs is objectionable noise and loss of modulation due to pulsating and/or a snap-closing action of the valve. • Pneumatic or analog electronic control. Variable air volume ( VAV) is a type of heating, ventilating, and/or air-conditioning ( HVAC) system. as an assembly, eliminating the need to mount coils a minimum of 36" (914) downstream or having to ship a bulky length of ductwork when coils are to be supplied mounted on the terminal. D3001 Single Duct Terminal Box 24×16 Inch Inlet. 08-29-2008. 45° rotation, CW to close. Nailor Industries Inc. GMAMCO LLC. • Digital VAV Terminal Units Catalog • November 1, 2022 (Supersedes: October 4, 2022 ). A Solid metal liner completely isolates the standard insulation and its raw edges from the airstream within. A series fan powered terminal unit, the 33SZ incorporates a cooling induction coil to use in conjunction with a DOAS (dedicated outdoor air system). Damper 38S UnderfloorFan Powered Inlet Duct Area K-Factor Velocity F-Factor Nailor's 3400 Series Mark II bypass terminal units utilize a unique cylindrical flow diverter valve for superior control and performance. Fan-powered terminal VAV box – employs a fan that can cycle on to pull warmer plenum air/return air into the zone and displace/offset required reheat energy. An 8” VAV box, typically sized for 800 cfm, would have to be accurate to 5% of 160 cfm (at Krueger’s recommended minimum airflow for that size), or +/-8 cfm, to comply with this requirement! It is more likely, however, that with reasonable inlet conditions, and a multi-point averaging sensor, mostNailor Subject: Single Duct Terminal Unit Model P3001 Keywords: Single Duct Terminal Unit Pneumatic Controls • Pressure Independent Variable Or Constant Volume Model P3001 Created Date: 3/16/2018 9:57:49 AMA. On a rise in room temperature, the 36VRS reduces the hot airflow. Bodily harm or death will occur if danger guidelines are not followed. Nailor Ceiling Radiation Dampers have been tested to UL 555C for use with air outlets in lay-in ceiling applications and UL 263 for Wood Truss ceiling assembly applications. They are specifically designed for precise air delivery throughout the entire operating range, regardless of the installed inlet conditions. The Air-Fi® WCI’s wireless mesh network is the perfect alternative to a wired communication link. Combination/Operable Louvers, Control, Smoke, and Combination Fire/Smoke Dampers utilize electric or pneumatic actuators. AT37SE - 3’ Long • for Models 37SE and 37SEST. Whether the requirement calls for a constant or variable air volume (VAV) single duct terminal, an electric or hot water reheat option or requires basic attenuation, the 3000 Series terminal units deliver. Johnson Controls Pneumatic VAV. - BLUE connects to LOW. Hanger brackets. IMPORTANT:Electric re-heat units ordered with SCR or SSR, route field wiring near bottom of control box. Northeast Ohio Sales rep for : CARNES- Fans, humidifiers, ERV. in monitoring overall vav box performance. • Richardson, TX 75081 Phone: (972) 680- 9136 | E-Mail: kruegerinfo@krueger-hvac. VAV COOLING CFM 0% 100% AIRFLOW VAV HEATING CFM 03 8 13 THERMOSTAT OUTPUT, PSI MIXING COOLING 18 0%. The fan runs in all modes during all occupied hours. Different sizes of HVAC diffusers can be used for the same airflow depending on the diffuser type. occupied mode . 1953 – Richard Hahn, Sr. 2038. Zip code search is only for US locations, for international provinces please select the country from the list. It is important during commissioning for many reasons. The primary air inlet is sized to provide conditioned, dehumidified air from a DOAS (dedicated outside air system) air handler, continuously. SINGLE DUCT TERMINAL UNIT WITH HOT WATER REHEAT • ACCESSORIES DIGITAL CONTROLS • PRESSURE INDEPENDENT The 35S Series provides many standard design features and superior sound performance when compared with other basic model designs. Single duct terminal VAV box – the simplest and most common VAV box, shown in Figures 1 and 2, can be configured as cooling-only or with reheating. Nailor 3000 Series Single Duct Variable Volume Terminal Units . Compare. ADD TO CART. Nailor 6200, 6400, and 6500 Series Pattern. Johnson Controls. All Nailor Fire/Smoke Dampers are tested and labeled in accordance with UL 555 and UL 555S. The purpose of this equipment O&M Best Practice is to. Download . Accessories. Excess air is diverted through a bypass opening and into the system return. reserves the right to change any information concerning product or pricing without notice. Nailor Fire Rated Diffusers are classified and listed by Underwriters Laboratory for use in UL/ULC restrained or unrestrained floor/ceiling and or roof/ceiling assemblies which incorporate an exposed grid suspended ceiling (lay-in T-Bar) with up. Nailor6. Literature. The Titus ESV is unique as it incorporates many design features that increase performance, decrease service and. This air handler configuration consists of custom-designed vertical air column units and VAV ECM fan booster boxes feeding perimeter linear convection heaters and high induction floor swirl diffusers in the interior that will be installed under the floors.